Updating Firmware for Dell ConnectX(TM) IB Mezzanine Cards
Please perform the following steps in order to update the firmware on your Mezzanine card:
- Download the firmware image from the following table
| ConnectX IB Mezzanine Cards Table | |||||
| Card Description | Card Rev: PSID* |
Device Name, PCI DevID (Decimal) | Firmware Image | Release Notes | Release Date |
| Dual IB DDR Mezzanine Card for Dell PowerEdge M600 and M605 | Rev
A1: DEL08C0000001 |
MT25408
ConnectX IB, PCI DevID: DDR - 25418 |
fw-25408- 2_3_000- MDI_A1.bin.zip | fw-25408 Rev 2_3_000 release notes.pdf | 4-Dec-07 |
* PSID
(Paremeter-Set
IDentification) is a 16-ascii character string embedded in the firmware
image which provides a unique identification for the configuration of
the firmware.
- Run “lspci | grep Mellanox” to determine the PCI bus ID
- Unzip the firmware image by running “unzip <firmware file name>.zip”
- You need the mstflint utility to update the firmware. You can download mstflint from the OpenFabrics site at mstflint_SW for Linux. (NOTE: If OFED is installed on your machine, then mstflint is already installed.)
- In the same directory as the firmware file, run “mstflint
–d <PCI bus ID, i.e. 05:00.0> -i <.bin file>
b”.
For details on mstflint usage -- see mstflint FW Burning Tool README - Reboot the system
- Run the “ibstat” command to verify the new firmware version